ID Country Sizing Province Nearest City Footage Insulation Temperature Scale Heating Demand Load Temperature Published
9343 Canada Size by Square Footage and Location Nova Scotia Dartmouth 3500 Medium N/A 0 0
9347 United States Size by Square Footage and Location Colorado Custer 2300 High N/A 0 0
9348 United States Size by Square Footage and Location Georgia Franklin 2100 High N/A 0 0
9349 United States Size by Square Footage and Location Georgia Franklin 02100 High N/A 0 0
9352 Canada Size by Square Footage and Location British Columbia Kimberley 2100 High N/A 0 0
9353 Canada Size by Square Footage and Location Alberta Red Deer 900 Medium N/A 0 0
9354 Canada Size by Square Footage and Location Newfoundland and Labrador St. John?s 3200 High N/A 0 0
9355 United States Size by Square Footage and Location Idaho Boundary 3000 Medium N/A 0 0
9356 United States Size by Square Footage and Location Alaska Kenai Peninsula 2000 High N/A 0 0
9357 Canada Size by Square Footage and Location Alberta Calgary 2000 Medium N/A 0 0
9358 United States Size by Square Footage and Location Alaska Kenai Peninsula 2000 Low N/A 0 0
9359 United States Size by Square Footage and Location Alaska Kenai Peninsula 2000 Medium N/A 0 0
9360 United States Size by Square Footage and Location Alaska 0 2200 Medium N/A 0 0
9361 United States Size by Square Footage and Location Alaska Ketchikan Gateway 2200 Medium N/A 0 0
9362 United States Size by Square Footage and Location Minnesota Polk 1128 Low N/A 0 0
9363 Canada Size by Square Footage and Location British Columbia Kimberley 2000 High N/A 0 0
9364 Canada Size by Square Footage and Location British Columbia Courtenay 800 Low N/A 0 0
9365 Canada Size by heating demand load and design temperature 0 0 0 Celsius 40000 -35
9366 Canada Size by Square Footage and Location Saskatchewan Nipawin 1400 Medium N/A 0 0
9367 United States Size by heating demand load and design temperature 0 0 0 Fahrenheit 10 17

*NOTE* This heat pump sizing tool does not consider cooling loads. There is a possibility that your cooling load is higher than your heating load, and as such the heat pump model suggested by this tool might not be appropriate for your project. This issue is most likely to effect customers based around the great lakes and in the southeast quarter of the U.S.A where summer humidity is high. If your project is located in these areas, a calculated cooling load needs to be considered. A manual J report can calculate the cooling load of your project accurately.

Arctic takes no responsibility for any cooling performance issues resulting from using this estimation to size a heat pump instead of a manual J.

If you would like Arctic to conduct a manual J for your project, please click the link below:

Arctic Heat pumps Logo

LET US HELP

OUR PRODUCTS

RESOURCES

RESOURCES