ID Country Sizing Province Nearest City Footage Insulation Temperature Scale Heating Demand Load Temperature Published
3029 United States Size by Square Footage and Location Alaska Juneau 1824 Low N/A 0 0
3030 Canada Size by Square Footage and Location Yukon Territory Whitehorse 800 Medium N/A 0 0
3031 United States Size by Square Footage and Location Pennsylvania Mercer 2000 Medium N/A 0 0
3032 United States Size by Square Footage and Location California San Francisco 2600 High N/A 0 0
3033 Canada Size by Square Footage and Location British Columbia Revelstoke 3280 High N/A 0 0
3034 United States Size by Square Footage and Location Colorado Boulder 3500 Medium N/A 0 0
3035 United States Size by Square Footage and Location California Tuolumne 4499 Medium N/A 0 0
3036 Canada Size by Square Footage and Location Alberta Edmonton 4100 Medium N/A 0 0
3037 Canada Size by Square Footage and Location Manitoba Winnipeg 1600 Medium N/A 0 0
3038 United States Size by Square Footage and Location Massachusetts Middlesex 1881 Medium N/A 0 0
3039 Canada Size by Square Footage and Location British Columbia Vancouver 3500 Medium N/A 0 0
3040 Canada Size by Square Footage and Location British Columbia Victoria 3500 High N/A 0 0
3041 Canada Size by Square Footage and Location British Columbia Nelson 2000 Medium N/A 0 0
3042 Canada Size by Square Footage and Location British Columbia Nelson 4000 Medium N/A 0 0
3043 United States Size by Square Footage and Location Washington Chelan 2700 Medium N/A 0 0
3044 Canada Size by heating demand load and design temperature 0 0 0 Celsius 30800 -20
3045 United States Size by Square Footage and Location Colorado Lake 2600 Medium N/A 0 0
3046 United States Size by Square Footage and Location Colorado Lake 2700 Low N/A 0 0
3047 United States Size by Square Footage and Location Colorado Lake 2600 High N/A 0 0
3048 Canada Size by Square Footage and Location Nova Scotia Halifax 2700 Medium N/A 0 0

*NOTE* This heat pump sizing tool does not consider cooling loads. There is a possibility that your cooling load is higher than your heating load, and as such the heat pump model suggested by this tool might not be appropriate for your project. This issue is most likely to effect customers based around the great lakes and in the southeast quarter of the U.S.A where summer humidity is high. If your project is located in these areas, a calculated cooling load needs to be considered. A manual J report can calculate the cooling load of your project accurately.

Arctic takes no responsibility for any cooling performance issues resulting from using this estimation to size a heat pump instead of a manual J.

If you would like Arctic to conduct a manual J for your project, please click the link below: