ID Country Sizing Province Nearest City Footage Insulation Temperature Scale Heating Demand Load Temperature Published
2302 United States Size by Square Footage and Location Colorado Eagle 1500 Medium N/A 0 0
2303 United States Size by Square Footage and Location Illinois Winnebago 2500 Medium N/A 0 0
2304 Canada Size by Square Footage and Location Saskatchewan Regina 3395 High N/A 0 0
2305 Canada Size by heating demand load and design temperature 0 Regina 3395 High Celsius 46993 -30
2307 United States Size by Square Footage and Location Pennsylvania Cambria 2000 Medium N/A 0 0
2308 United States Size by Square Footage and Location Vermont Orleans 4000 High N/A 0 0
2309 Canada Size by Square Footage and Location Nova Scotia Bridgewater 3000 Medium N/A 0 0
2310 United States Size by Square Footage and Location Maryland Charles 1500 Medium N/A 0 0
2311 United States Size by Square Footage and Location Alaska Anchorage Municipality 3000 Medium N/A 0 0
2312 United States Size by Square Footage and Location Alaska Anchorage Municipality 3000 Medium N/A 0 0
2313 Canada Size by Square Footage and Location Nova Scotia Dartmouth 2500 High N/A 0 0
2314 Canada Size by Square Footage and Location Nova Scotia Dartmouth 2500 Medium N/A 0 0
2315 United States Size by Square Footage and Location Colorado Denver 2000 Medium N/A 0 0
2316 Canada Size by Square Footage and Location Quebec Magog 2000 High N/A 0 0
2317 United States Size by Square Footage and Location Alaska Kenai Peninsula 1500 High N/A 0 0
2318 Canada Size by Square Footage and Location British Columbia Victoria 1500 Medium N/A 0 0
2319 Canada Size by Square Footage and Location Prince Edward Island Summerside 1700 Medium N/A 0 0
2320 Canada Size by Square Footage and Location Prince Edward Island Summerside 3600 Medium N/A 0 0
2321 United States Size by Square Footage and Location Alaska Juneau 2100 High N/A 0 0
2322 United States Size by Square Footage and Location Alaska Juneau 2100 Medium N/A 0 0

*NOTE* This heat pump sizing tool does not consider cooling loads. There is a possibility that your cooling load is higher than your heating load, and as such the heat pump model suggested by this tool might not be appropriate for your project. This issue is most likely to effect customers based around the great lakes and in the southeast quarter of the U.S.A where summer humidity is high. If your project is located in these areas, a calculated cooling load needs to be considered. A manual J report can calculate the cooling load of your project accurately.

Arctic takes no responsibility for any cooling performance issues resulting from using this estimation to size a heat pump instead of a manual J.

If you would like Arctic to conduct a manual J for your project, please click the link below: